[ Identification | Description | Input parameters | Links ]
Test_PowderN
InstrumentSimply a model source illuminating a powder sample. The default sample itself is an LaB6-powder. Alternatively, the Single_crystal component can also be tested in powder mode.
Name | Unit | Description | Default |
E0 | keV | Source energy (width 1 keV) | 15 |
L1 | m | Source-sample distance | 10 |
directbeam | 1 | Suppress direct beam (0) or not (1) | 0 |
reflections | str | List of powder reflections, LAU/CIF format. | "LaB6_660b_AVID2.hkl" |
SPLITS | 1 | Number of SPLIT's before sample | 1 |
frac_c | 1 | Fraction of stats assigned to coherent scattering | 0.8 |
frac_i | 1 | Fraction of stats assigned to incoherent scattering | 0.1 |
frac_t | 1 | Fraction of stats assigned to unscattered, "direct beam" | 0.1 |
d_phi | deg | Angle corresponding to the vertical angular range to focus to, e.g. detector height. 0 for no focusing. | 0 |
TTH | deg | Rotation of secondary detector arm. | 0 |
index | 1 | Index of the sample component to use. 1=PowderN, 2=Single_crystal | 1 |
Test_PowderN.instr
.
[ Identification | Description | Input parameters | Links ]
Generated on 2024-07-01 12:32:10