loading system configuration loading override configuration from /users/willend/mxtest/mctest/../mccodelib/mcxtrace-test/McXtrace_DUAL_A100_DMSC/mccode_config.json INFO: Using directory: "2" INFO: Using existing c-file: ./Test_Filter.c INFO: Using existing binary: ./Test_Filter.out INFO: === -------------------------------------------------------------------------- WARNING: No preset parameters were found for the device that Open MPI detected: Local host: r6n22 Device name: mlx5_0 Device vendor ID: 0x02c9 Device vendor part ID: 4123 Default device parameters will be used, which may result in lower performance. You can edit any of the files specified by the btl_openib_device_param_files MCA parameter to set values for your device. NOTE: You can turn off this warning by setting the MCA parameter btl_openib_warn_no_device_params_found to 0. -------------------------------------------------------------------------- Simulation 'Test_Filter' (/users/willend/xTESTS/2022-12-01/McXtrace_DUAL_A100_DMSC_5e7/Test_Filter/Test_Filter.instr): running on 2 nodes (master is 'r6n22.esss.dk', MPI version 3.1). Have found 2 GPU devices on rank 1. Will use device 1. Have found 2 GPU devices on rank 0. Will use device 0. [Test_Filter] Initialize [Test_Filter] Initialize Opening input file '/users/willend/McXtrace/mcxtrace/3.x-dev/tools/Python/mxrun/../mccodelib/../../../data/Rh.txt' (Table_Read_Offset) WARNING: (Table_Rebin): Rebinning table from Rh.txt would exceed 1M rows. Skipping. filter: Rebinning material data (Rh.txt) for faster tracing...done WARNING: (Table_Rebin): Rebinning table from Rh.txt would exceed 1M rows. Skipping. filter: Rebinning material data (Rh.txt) for faster tracing...done Reusing input file 'Rh.txt' (Table_Read_Offset) filter2: Rebinning material data (Rh.txt) for faster tracing...done WARNING: (Table_Rebin): Rebinning table from Rh.txt would exceed 1M rows. Skipping. WARNING: (Table_Rebin): Rebinning table from Rh.txt would exceed 1M rows. Skipping. filter2: Rebinning material data (Rh.txt) for faster tracing...done *** TRACE end *** Save [Test_Filter] Detector: l_mon0_I=0.000794121 l_mon0_ERR=1.12306e-07 l_mon0_N=5e+07 "l_mon0.dat" Finally [Test_Filter: 2]. Time: 1 [s] Detector: l_mon1_I=4.02976e-29 l_mon1_ERR=4.95807e-32 l_mon1_N=4.99795e+07 "l_mon1.dat" Finally [Test_Filter: 2]. Time: 1 [s] [r6n22.esss.dk:3412167] 1 more process has sent help message help-mpi-btl-openib.txt / no device params found [r6n22.esss.dk:3412167] Set MCA parameter "orte_base_help_aggregate" to 0 to see all help / error messages INFO: Placing instr file copy /users/willend/xTESTS/2022-12-01/McXtrace_DUAL_A100_DMSC_5e7/Test_Filter/Test_Filter.instr in dataset 2